Currently this applies to our SAM 12 and SAM 35 Suction units as large numbers of these units have been specifically supplied although it is intended that this page will be expanded to include additional support information for other SAM models over the coming weeks and months. At the moment, the additional information includes ;. Technical Details for the unit. A basic training presentation. Details of key consumables.
It is intended that training videos will also be added to further assist both end user medics and support engineers. SAM 12 Suction Unit. Clicking on the buttons below will open up a new window in your browser with the appropriate information for the SAM 12 suction unit. SAM 35 Suction Unit. All UPS subassemblies, as well as the battery, shall be accessible from the front. To that end, the UPS shall be equipped with a self-test function to verify correct system operation.
The self-test function shall identify the subassembly requiring repair in the event of a fault. The electronic UPS control and monitoring assembly shall therefore be fully microprocessor based, thus doing away with all potentiometer settings. This shall allow:. Extensive acquisition of information vital for computer-aided diagnostics local or remote ;. The UPS shall be repairable by replacing standard subassemblies requiring no adjustments.
Communication via a modem with a remote maintenance system shall be possible. Approved Manufacturer s : The specified equipment will be manufactured by APC by Schneider Electric or approved manufacturer in compliance with specifications. Product Description : This specification describes a three-phase, double conversion, on-line, solid state Uninterruptible Power System, hereafter referred to as the UPS.
The UPS shall operate in conjunction with the existing building electrical system to provide power conditioning, back-up power protection and distribution for electronic equipment loads. Output voltage : VAC 3 phase, 3 plus ground. Inrush Current : less than nominal input current for less than one cycle. Power Factor : 0. The UPS module shall be designed to operate as a double conversion, on-line reverse transfer system in the following modes.
Normal : The inverter shall continuously supply power to the critical load. The PFC rectifier shall derive power from the utility AC source and supply DC power to the inverter while simultaneously float charging the battery. Emergency : Upon failure of the utility AC power source, the critical load shall be supplied by the inverter, which, without any interruption, shall obtain its power from the battery.
Recharge : Upon restoration of the utility AC power source prior to complete battery discharge , the PFC rectifier shall power the inverter and simultaneously recharge the battery. Bypass Mode : The static bypass transfer switch shall be used to transfer the load to the bypass without interruption to the critical power load. This shall be accomplished by turning the inverter off.
Automatic re-transfer or forward transfer of the load shall be accomplished by turning the inverter on. The PFC rectifier shall provide high quality DC power to charge the batteries and power the inverter and shall have the following characteristics:.
Charging Levels : The battery charging circuitry shall be capable of being set for automatic battery recharge operation, float service, manual battery charge service, and equalizing or commissioning operation.
Intermittent Charging : The battery charge level shall be maintained by an intermittent charging technique between two values Vfmin and Vfmax very close to the floating voltage. This technique shall be based on a cycle made up of a short charge period a few seconds from Vfmin to Vfmax followed automatically by a slow discharge period a few minutes from Vfmax to Vfmin.
This cycle shall be repeated continuously to maintain the battery charge level. In this way the battery shall actually be charging only for a small part of the time, which considerably increases its service life. IGBT inverter design. The inverter shall be capable of providing the specified precise output power characteristics while operating over the battery voltage range. Welcome to ManualMachine. We have sent a verification link to to complete your registration.